<ErrorNumber>10064</ErrorNumber>
<ErrorFamily>Hardware</ErrorFamily>
<ErrorMessage>
HARDWARE: External Debris Blower Not Connected or Filters Full (Vacuum Level %d is below %d)
</ErrorMessage>
<AppliesTo>
<UnnumberedList>
<ListItem><Text>All</Text></ListItem>
</UnnumberedList>
</AppliesTo>
<ServiceInformation>
<DescriptionText><text>
The vacuum sensor at the debris nozzle is reading much lower than normal.  It has dropped below
the value specified in "sys dbls".  The low vacuum level is displayed as part of the error message,
as is the threshold level.
</text></DescriptionText>
<DescriptionText><text>
This either indicates that the debris filter is full and should be replaced, or that a sensor
calibration error has occured.
</text></DescriptionText>
<DescriptionText><text>
FILTER FULL
</text></DescriptionText>
<DescriptionText><text>
If the filter is full, the operators have most likely been ignoring warnings being reported
over the past while.  Check for warning logs, and tell them what to look for.  With the Allegro
workstation software, the warnings will have been displayed in the small box on the main GUI
page.  With Print Console, the warnings will have been large prompts coming up in the main
message window.
</text></DescriptionText>
<DescriptionText><text>
CALIBRATION ERROR
</text></DescriptionText>
<DescriptionText><text>
If the filter is not full, and an invalid calibration is suspected, leave the output device idle for
ten minutes so that the debris cabinet turns off automatically then wait 30 seconds before running a
new job to delay activation of the debris cabinet. This pause allows pressure at the sensor to stabilize
to normal room pressure before sensor calibration occurs.  Alternatively, from the diagnostic port, the
command "dr off" will turn the debris cabinet off immediately. Then wait 30 seconds to make sure the
pressure returns to normal. You can check with the command "dr" to see when the vacuum readings stop
changing. Use the command "dr on" to recalibrate the sensor and turn the cabinet on.
</text></DescriptionText>
</ServiceInformation>
<OperatorAction>
<DescriptionText><text>
The device thinks the debris filter inside the debris cabinet is full.  Open the cover of the
cabinet and inspect the filter, replacing it if necessary.  If the filter is not full, wait 30 seconds after
the debris system shuts off (to force recalibration of the sensor) and then continue.  If the problem comes
back, contact the CreoScitex Response Centre.
</text></DescriptionText>
</OperatorAction>
<Cause>
Filter is full.
</Cause>
<Cause>
If the cabinet is turned on within 30 seconds of being turned off, the debris nozzle vacuum sensor may
not calibrate correctly.  As a result, the vacuum sensor readings are too low and the above error message
is generated.  The most likely occurrence is when a new plot happens immediately after the 10-minute
automatic shut-off.
</Cause>
<Cause>
Hoses or sensor lines not connected or are leaking.
</Cause>
<Cause>
Failure of analog board/jumper.
</Cause>
<SeeAlso>
<UnnumberedList>
<Link><LinkAddress>../commands/dr.xml</LinkAddress><LinkTitle>Command: dr</LinkTitle></Link>
<Link><LinkAddress>../nvs/sys_cfg_dbls.xml</LinkAddress><LinkTitle>NVS: sys dbls</LinkTitle></Link>
</UnnumberedList>
</SeeAlso>
<OtherLinks>
<Link><LinkAddress>..\..\ShowAllErrors.htm</LinkAddress><LinkTitle>Firmware 0 Error Index</LinkTitle></Link>
<Link><LinkAddress>..\..\ShowAllCommands.htm</LinkAddress><LinkTitle>Firmware 0 Command Index</LinkTitle></Link>
<Link><LinkAddress>..\..\ShowAllNVS.htm</LinkAddress><LinkTitle>Firmware 0 NVS Index</LinkTitle></Link>
</OtherLinks>
<Updated>
Updated: Wed Jul 16 19:32:31 2008 PST
</Updated>
<Links>
</Links>
</Error>